About us
DN40-300mm
electromagnetic water meter is specially designed for the water industry to meet the needs of urban water supply and water resources management systems. It is suitable for water metering and DMA zone metering for large customers, and provides a large amount of stored data to ensure accurate trade settlement. It is widely used in areas without power supply on site. Places such as urban water supply, sewage treatment, water conservancy projects, etc.
Product features
◆Wide range ratio and wide application range
◆Low initial flow rate, with ultra-low lower limit measurement capability
◆The memory is made of environmentally friendly materials and can be used for drinking water
◆There are no mechanical moving parts inside the water meter
◆Supports single and bidirectional measurement functions
◆Battery life span 6 More than 10 years old
◆ There are no flow-blocking parts in the measuring tube, small pressure loss, and low requirements for straight pipe sections
◆ Variable diameter design, Improve measurement accuracy and sensitivity, reduce excitation power consumption
◆ Reasonable selection of electrodes and linings, with good corrosion resistance and wear resistance
◆ Fully electronic design, strong anti-interference ability, reliable measurement, high accuracy, wide range
◆ Microprocessor Technology, fast computing speed, high precision, low-frequency rectangular wave excitation, adjustable excitation frequency, low power consumption design
Technical parameters |
|||||||||||
Nominal diameter |
DN |
mm |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
250 |
300 |
Common traffic |
Q3 |
m³/h |
40 |
63 |
100 |
160 |
250 |
400 |
630 |
1000 |
1600 |
Turndown* |
Q₃/Q₁ |
|
500 |
500 |
500 |
500 |
500 |
500 |
500 |
500 |
500 |
|
Q₂/Q₁ |
m³/h |
1.6 |
1.6 |
1.6 |
1.6 |
1.6 |
1.6 |
1.6 |
1.6 |
1.6 |
overload traffic |
Q₄ |
m³/h |
50 |
77.75 |
125 |
200 |
312.5 |
500 |
787.5 |
1250 |
2000 |
Demarcation traffic |
Q₂ |
m³/h |
0.128 |
0.2016 |
0.32 |
0.512 |
0.8 |
1.28 |
2.016 |
3.2 |
5.12 |
minimum flow |
Q1 |
m³/h |
0.08 |
0.126 |
0.2 |
0.32 |
0.5 |
0.8 |
1.26 |
2 |
3.2 |
Pressure loss level |
|
|
△p40 |
||||||||
Display range |
min |
m³ |
0.0001 |
||||||||
|
max |
m³ |
999,999,999 |
||||||||
length |
L |
mm |
200 |
200 |
200 |
250 |
250 |
300 |
350 |
450 |
500 |
width |
B |
mm |
165 |
185 |
200 |
220 |
250 |
285 |
340 |
405 |
460 |
high |
H |
mm |
328 |
340 |
355 |
365 |
370 |
413 |
489 |
530 |
588 |
Temperature level |
T50 |
||||||||||
pressure level |
MAP16 |
||||||||||
Traffic sensitivity level |
U0/D0 |
||||||||||
environmental level |
O level |
||||||||||
Electromagnetic environment level |
E2 |
||||||||||
accuracy level |
Level 2 |
||||||||||
Communication method |
NB-IOT, GPRS, RS-485 |